Submersible level and temperature transmitters - Submersible level and temperature transmittersd Füllstandsmessung



productpicture_atm-1st-n-t_web.jpg

ATM.1ST/N/T

Features

  • Pressure measuring range: 1 … 250 mH2O
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Temperature measuring range: -5 … 80°C
  • Operating temperature: -5 … 80°C
  • Process temperature: -5 … 80°C
  • Output signal: 4 … 20 mA
  • Materials: Stainless steel, Titanium



productpicture_atm-1st-n_web.jpg

ATM.1ST/N

Features

  • Pressure measuring range: 1 … 250 mH2O
  • Accuracy: ≤ ± 0.10 % FS
  • Total Error Band: ≤ ± 0.30 %FS (-5 … 50°C)
  • Operating temperature: -5 … 80°C
  • Process temperature: -5 … 80°C
  • Output signal: 0 … 5 / 0 … 10 VDC, 4 … 20 mA
  • Materials: Stainless steel, Titanium
  • Feature: Optional overvoltage protection

Customer benefits

  • High precision pressure sensor over the whole temperature range
  • Electronic compensation
  • Any process connections available
  • Can be ordered in different materials



productpicture_atm-1st-n-ex_web.jpg

ATM.1ST/N/Ex

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.10 % FS
  • Total Error Band: ≤ ± 0.30 %FS (-5…50 °C)
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel, Titanium

Customer benefits

  • Various certificates available
  • High precision pressure sensor over the whole temperature range
  • Electronic compensation
  • Any process connections available
  • Can be ordered in different materials



productpicture_atm-eco-n_web.jpg

ATM.ECO/N

Features

  • Pressure measuring range: 1 … 250 mH2O
  • Accuracy: ≤ ± 0.25 % FS
  • Total Error Band: ≤ ± 0.70 %FS (-5 … 50°C)
  • Operating temperature: -5 … 80°C
  • Process temperature: -5 … 80°C
  • Output signal: 0 … 5 / 0 … 10 VDC, 4 … 20 mA
  • Materials: Stainless steel

Customer benefits

  • Optimal price-quality ratio
  • Electronic compensation
  • Any process connections available
  • Can be ordered in different materials



productpicture_atm-eco-n-ex_web.jpg

ATM.ECO/N/Ex

Features

  • Pressure measuring range: 1 … 250 mH2O
  • Accuracy: ≤ ± 0.25 % FS
  • Total Error Band: ≤ ± 0.70 %FS (-5 … 50°C)
  • Operating temperature: -5 … 80°C
  • Process temperature: -5 … 80°C
  • Output signal: 4 … 20 mA
  • Materials: Stainless steel

Customer benefits

  • Various certificates available
  • Optimal price-quality ratio
  • Electronic compensation
  • Any process connections available
  • Can be ordered in different materials



productpicture_atm-n_web.jpg

ATM/N

Features

  • Pressure measuring range: 1 … 250 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -5 … 80°C
  • Process temperature: -5 … 80°C
  • Output signal: 0 … 5 / 0 … 10 VDC, 0 … 20 / 4 … 20 mA
  • Materials: Stainless steel, Titanium
  • Feature: Optional overvoltage protection

Customer benefits

  • Any process connections available
  • Recalibration possible
  • Available with overvoltage protection
  • Can be ordered in different materials



productpicture_atm-n-ex_web.jpg

ATM/N/IS

Features

  • Pressure measuring range: 1 … 250 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -5 … 80°C
  • Process temperature: -5 … 80°C
  • Output signal: 4 … 20 mA
  • Materials: Stainless steel, Titanium
  • Feature: Optional overvoltage protection

Customer benefits

  • Various certificates available
  • Optimal price-quality ratio
  • Any process connections available
  • Can be ordered in different materials



productpicture_atm-n-ex_web.jpg

ATM/N/Ex

Features

  • Pressure measuring range: 1 … 250 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -5 … 80°C
  • Process temperature: -5 … 80°C
  • Output signal: 4 … 20 mA
  • Materials: Stainless steel, Titanium
  • Feature: Optional overvoltage protection

Customer benefits

  • Various certificates available
  • Optimal price-quality ratio
  • Any process connections available
  • Can be ordered in different materials



productpicture_atm-n-t_web.jpg

ATM/N/T

Features

  • Pressure measuring range: 1 … 250 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Temperature measuring range: -5 … 80°C
  • Operating temperature: -5 … 80°C
  • Process temperature: -5 … 80°C
  • 2 Output signals (p & T): 0 … 10 VDC, 0 … 20 / 4 … 20 mA
  • Materials: Stainless steel, Titanium

Customer benefits

  • Multi-parameter diving probe: pressure and temperature
  • Can be ordered in different materials



productpicture_atm-n-19_web.jpg

ATM/N 19

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 0 … 5 / 0 … 10 VDC, 4 … 20 mA
  • Materials: Stainless steel
  • Feature: 19 mm diameter

Customer benefits

  • Small dimensions, suitable for 1'' tubes



productpicture_atm-k-n_web.jpg

ATM/K/N

Features

  • Pressure measuring range: 1…200 mH2O
  • Accuracy: ≤ ± 0.25 % FS
  • Operating temperature: -5…50 °C
  • Process temperature: -5…50 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel
  • Feature: Optional surge (lightning) protection

Customer benefits

  • Ceramic measuring cell
  • Robust version



productpicture_atm-nc_web.jpg

ATM/NC

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 2.0 % FS
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 0…5 / 0…10 V DC, 0…20 / 4…20 mA
  • Materials: PVDF
  • Feature: Optional surge (lightning) protection

Customer benefits

  • With regard to chemical resistance, a unique sensor on the market
  • High media compatibility thanks to a special PVDF-housing



productpicture_atm-nc-ex_web.jpg

ATM/NC/Ex

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 2.0 % FS
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 4…20 mA
  • Materials: PVDF
  • Feature: Optional surge (lightning) protection

Customer benefits

  • With regard to chemical resistance, a unique sensor on the market
  • High media compatibility thanks to a special PVDF-housing



DTM.OCS_2.jpg

DTM.OCS.S/N

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.15 / 0.05 / 0.03 % FS
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Interface: RS485
  • Materials: Stainless steel, Titanium

Customer benefits

  • Digital pressure sensor
  • Any process connections available
  • Can be ordered in different materials



productpicture_ptm-n_web.jpg

PTM/N

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Adjustable 1:4 of the nominal range within -5% to +105%
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel, Titanium
  • Feature: Recalibration with software possible

Customer benefits

  • Scalable pressure ranges and output signals
  • Flexibly applicable pressure sensor
  • Any process connections available
  • Available with lightning protection
  • Can be ordered in different materials



productpicture_ptm-n-ex_web.jpg

PTM/N/Ex

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Adjustable 1:4 of the nominal range within -5% to +105%
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel, Titanium
  • Feature: Recalibration with software possible

Customer benefits

  • Various certificates available
  • Scalable pressure ranges and output signals
  • Flexibly applicable pressure sensor
  • Any process connections available
  • Can be ordered in different materials



productpicture_ptm-n-rs-485_web.jpg

PTM/N/RS485

Features

  • Pressure measuring range: 1…250 mH2O
  • Adjustable 1:4 of the nominal range within -5% to +105% (analog output)
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Temperature measuring range: -25…85 °C
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • 2 Output signals (p & T): 4…20 mA
  • Interface: RS485 (Modbus RTU)
  • Materials: Stainless steel, Titanium
  • Feature: Recalibration with software possible, optional surge (lightning) protection

Customer benefits

  • Scalable pressure ranges and output signals
  • Flexibly applicable pressure sensor
  • Digital and analogue output signal in one sensor
  • Available as multi-parameter sensor (pressure & temperature)
  • Any process connections available
  • Available with lightning protection
  • Can be ordered in different materials



productpicture_ptm-n-sdi-12_web.jpg

PTM/N/SDI-12

Features

  • Pressure measuring range: 5…250 mH2O
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Temperature measuring range: -25…85 °C
  • Operating temperature: -5…50 °C
  • Process temperature: -5…50 °C
  • Interface: SDI-12 (V1.3)
  • Materials: Stainless steel, Titanium
  • Feature: Recalibration possible, Adjustable units

Customer benefits

  • Scalable pressure ranges and output signals
  • Flexibly applicable pressure sensor
  • Any process connections available
  • Available including lightning protection
  • Can be ordered in different materials



productpicture_mtm-n-10_web.jpg

MTM/N 10

Features

  • Pressure measuring range: 10…100 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25
  • Operating temperature: -5…50 °C
  • Process temperature: -5…50 °C
  • Output signal: mV
  • Materials: Stainless steel, Titanium
  • Feature: Level transmitter with 10 mm diameter, Version with ATM/N possible

Customer benefits

  • Submersible level transmitter with a very small diameter
  • Both passive and active versions can be ordered



productpicture_tm-n_web.jpg

TM/N

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25 % FS
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: mV
  • Materials: Stainless steel, Titanium

Customer benefits

  • Unreinforced output signal
  • Any process connections available
  • Can be ordered in different materials



productpicture_tm-n-ex_web.jpg

TM/N/Ex

Features

  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25 % FS
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: mV
  • Materials: Stainless steel, Titanium

Customer benefits

  • Various certificates available
  • Unreinforced output signal
  • Any process connections available
  • Can be ordered in different materials